Evaluation of Surface Cracks Using Magnetic Flux Leakage Testing
摘要
The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The results showed that crack width and lift-off (the distance between surface and sensor) will influence signals. Discussed in this paper is the influence of various lift-off parameters on the peak to peak values of the normal component in magnetic flux leakage testing. The effects can be applied to evaluate surface breaking cracks of different widths and depths.An idea is presented to smooth narrow, sharp crack tips using alternating current (AC) field magnetization.
引用本文(GB/T 7714)
LumingLI, SonglingHUANG. Evaluation of Surface Cracks Using Magnetic Flux Leakage Testing[J]. Acta Scientiarum Naturalium Universitatis Sunyatseni, 2002.
引文网络