首页 / 资料库 / 文献详情

Off-Line Identification of Induction Motor Parameters

LiuJunfengLuoHuiWanShuyun

2005电气:英文版Engineering被引 5

出版方页面 →

摘要

This study presented an off-line identification method of induction motor (IM) parameters. Before startup,the inverter drive performed automatically a modified DC test, a locked-rotor test, a no-load test and a step-voltage test to identify all the parameters of an induction motor. No manual operation and speed signals were required in the process. In order to obtain effective messages and improve the accuracy of identification, the discrete fast Fourier transform (DFFT) and the least-squares were used to process the signals of currents and voltages. A phase-voltage measuring method for motors was also proposed, which measured directly the actual conducting time of three upper switches in the inverter without need for a dead-time compensator. The validity, reliability and accuracy of the presented methods have been verified by the experiments on a VSI-fed IM drive system.

引用本文(GB/T 7714)

LiuJunfeng, LuoHui, WanShuyun. Off-Line Identification of Induction Motor Parameters[J]. 电气:英文版, 2005.

引文网络

参考文献与被引分析加载中…

本站仅收录题录与摘要供学习参考,全文版权归属出版方;如有侵权请联系我们删除。