OBJECTIVE: To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA). METHODS: . The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded. RESULTS: >0.05). CONCLUSION: The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.