首页 / 资料库 / 文献详情

INFLUENCE OF CHANGING SHEAR ADJUSTMENT STRATEGY ON ASEISMIC PERFORMANCE OF FRAME-CORE TUBE STRUCTURE

Xinzheng LuDonglian GuZhou JianlongLianjin BaoQian PengLu XiaoLin Yuan-qing

2019工程力学Engineering被引 2

出版方页面 →

摘要

The frame-core-tube structural system is one of the common structural systems used in supertall buildings. While a shear adjustment regulation for the frame of a frame-core tube structure has been specified in related Chinese codes, its applicability in supertall buildings needs to be further studied. Similar regulations in the codes of China and the United States are compared in this work. Furthermore, based on an actual supertall building, a new design is proposed by changing the shear adjustment strategy. Then the refined finite element (FE) models of both original design and new one are established. And both nonlinear time history analysis (THA) under the maximum considered earthquake (MCE) and earthquake-induced collapse analysis are performed for these two models. The results indicate that:compared with the original design, the new one, whose shear adjustment strategy is different, has a lower design difficulty, a similar aseismic performance under MCE, and a higher anti-collapse resistance. The results can provide a reference for the design of supertall frame-core tube structures.

引用本文(GB/T 7714)

Xinzheng Lu, Donglian Gu, Zhou Jianlong, 等. INFLUENCE OF CHANGING SHEAR ADJUSTMENT STRATEGY ON ASEISMIC PERFORMANCE OF FRAME-CORE TUBE STRUCTURE[J]. 工程力学, 2019.

引文网络

参考文献与被引分析加载中…

DOI:https://doi.org/10.6052/j.issn.1000-4750.2017.11.0853

本站仅收录题录与摘要供学习参考,全文版权归属出版方;如有侵权请联系我们删除。