首页 / 资料库 / 文献详情

平板光学元件微扫描性能影响因素的研究

Xiubao SuiLianfa BaiQian ChenGuohua Gu

2011Chinese Optics LettersEngineering被引 19开放获取

出版方页面 →

摘要

To decrease the performance difference between the actual microscanning thermal imager and the theoretical value, a germanium lens (placed at a certain angle between the infrared focal plane array and infrared lens) dip angle model of flat optical component microscanning is introduced in this letter. The model is the basis for choosing the dip angle of the germanium lens, which is used in the microscanning thermal imager. In addition, the actual dip angle of the germanium lens is chosen according to the model, the infrared lens parameters of the thermal imager, and the germanium lens parameters of manufacture and installation. Only in this manner can the optimal performance of the microscanning thermal imager based on the flat optical component be obtained. Results of the experiments confirm the accuracy of the conclusions above.

引用本文(GB/T 7714)

Xiubao Sui, Lianfa Bai, Qian Chen, 等. 平板光学元件微扫描性能影响因素的研究[J]. Chinese Optics Letters, 2011.

引文网络

参考文献与被引分析加载中…

DOI:https://doi.org/10.3788/col201109.052302

本站仅收录题录与摘要供学习参考,全文版权归属出版方;如有侵权请联系我们删除。