Experimental study on full-scale steel beam-to-column moment connections

钱稼茹余海群颜锋董海李建华刘月明

2005地震工程与工程振动:英文版Engineering被引 2

出版方页面 →

摘要

Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one traditional welded flange-bolted web connection, one traditional fully welded connection, four beam flange strengthened connections,three beam flange weakened connections, and one through-diaphragm connection. The test results show that the connections with flange cover plates or with partly cut beam flanges satisfy the beam plastic rotation demand for ductile MRFs. From the measured stress profiles along the beam flange and beam web depth, the mechanics of brittle fracture at the end of the beam is discussed. Design recommendations for steel beam-to-column moment connections are proposed.

引用本文(GB/T 7714)

钱稼茹, 余海群, 颜锋, 等. Experimental study on full-scale steel beam-to-column moment connections[J]. 地震工程与工程振动:英文版, 2005.