首页 / 资料库 / 文献详情

DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER

JIANGYan-longCHENGuobangTHUMMESGuenter

2004Acta Scientiarum Naturalium Universitatis SunyatseniEngineering被引 1

出版方页面 →

摘要

An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively.

引用本文(GB/T 7714)

JIANGYan-long, CHENGuobang, THUMMESGuenter. DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER[J]. Acta Scientiarum Naturalium Universitatis Sunyatseni, 2004.

引文网络

参考文献与被引分析加载中…

本站仅收录题录与摘要供学习参考,全文版权归属出版方;如有侵权请联系我们删除。