首页 / 资料库 / 文献详情

Effect of Air Gap under Fabric on Thermal Protective Performance Using an Improved Apparatus

李小辉卢业虎周亮李 俊王云仪

2011东华大学学报:英文版Medicine被引 1

出版方页面 →

摘要

The bench top test is one of the most important and effective methods to evaluate the total thermal protective performance(TPP) of firefighters’ protective clothing,which is greatly influenced by the air gaps entrapped.In this paper,to investigate the effect of air gap width on TPP,a new improved apparatus with two height changeable buttons to hold the thermal sensor was developed to get a series of air gap sizes from 0 mm to 40 mm.The TPP of two types of flame-resistant outer fabrics was measured with TPP test apparatus respectively.Analysis of temperature rise with each air gap width was made to determine the effects of different air gaps on protective performance.It was indicated that air gap size had great effect on TPP of fabrics in the bench top test.An air gap width above 8 mm was suggested for the thermal protective clothing design.

引用本文(GB/T 7714)

李小辉, 卢业虎, 周亮, 等. Effect of Air Gap under Fabric on Thermal Protective Performance Using an Improved Apparatus[J]. 东华大学学报:英文版, 2011.